Electric & Gaffer β’ GRIPEDIA ENTRY
Wet-Set Class A GFCI (4-6 mA)
Also Known As:Ground-Fault Circuit InterrupterRain Safety Breaker
Life-saving electrical interrupter tripping inside 25 milliseconds on tiny 4-6 mA current leaks; vital whenever filming in rain or puddles because soaked human skin drops resistance from 100,000 ohms down to ~500-1,000 ohms.
Technical Infobox & Standards
Specification / Protocol: Trip Curve: 4-6 mA in < 25 ms (CSATF Bulletin #23 / NEC Art. 530) | Test and reset manually at every morning wet call!
Knowledge Topic: Rigging Physics, Safety & Codes β’ Origin Reference: Hollywood, California, USA (Norms Studio Equipment, Est. 1962)
Primary Sources & Standards: CSATF Safety Bulletins & Industry Experience Roster (#8, #10, #22, #23) Β· NFPA 70 (NEC Art. 530) & NFPA 13 Film Stage Fire Protection
Wet-Set Class A GFCI (4-6 mA)